Steel Buildings in Europe
        
 Part 2: Concept Design 2 - 25 7.5 m 6 m 6 m 48 m 13.5 m T L L T S L S L – Lift; S – Stairs; T – Toilets Figure 4.1 Column grid for a naturally ventilated office 7.5 m 7.5 m 7.5 m 7.5 m 15 m 15 m 30 m 15 m 60 m 45 m L T L L L L T S S L S L – Lift; S – Stairs; T – Toilets Figure 4.2 Column grid for long span floor in a prestige air conditioned office 4.2 Dimensional coordination The choice of the basic building shape is usually the Architect’s responsibility, constrained by such issues as th e site plan, access, building orien tation, parking, landscaping and local planni ng requirements. The following general guidance influences the choice of structure.  Between sources of natural light there should be 13,5 m and 20 m intervals  Naturally lit and ventilated zone s extend a distan ce of twice the floor-to-ceiling height from the outer wa lls – artificial li ght and ventilation is required in other zones
        